KL10-0.6/1.8-110 Stationary anode X-Ray tube is especially designed for Mobile Units for radiography, for Portable Radiographic Units, and available for a nominal tube voltage with high frequency or DC generator. The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode. The high anode heat storage capacity ensures a wide range of applications for mobile, portable applications. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

Technical data

Nominal Tube Voltage 110kV
Nominal Focal Spot small:0.6   large:1.8(IEC60336/2005)
Filament Characteristics small:Ifmax=4.5A,Uf=5±0.5  large:Ifmax=4.5A,Uf=6.3±0.8V
Nominal Input Power(at 1.0s) small:spot0.6kW  large:spot5.2kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 30kJ
Target Angle 15°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx600g

Competitive Advantage

Elevated anode heat storage capacity and cooling Constant high dose yield Excellent lifetime

Applications

KL10-0.6/1.8-110 Stationary anode X-Ray tube is especially designed for Mobile Units for radiography, for Portable Radiographic Units, and available for a nominal tube voltage with high frequency or DC generator.

Detailed Images

AKL10-0.6-1.8-110Maintaining seasoning schedule Prior to usage, season the tube in accordance with the seasoning schedule given below until the required tube voltage is attained. Example given – needs to revise by the manufacturer and specified in the data sheet of the part: Initial incoming seasoning and seasoning schedule for idle period (more than 6 months) Circuit: DC (Center grounded) KL10 老练图 When the tube current is unstable in seasoning, immediately switch off the tube voltage and after an interval of 5 minutes or more, increase the tube voltage gradually from the low voltage while making sure that the tube current is stable. The withstand voltage performance of the tube unit will be lowered as the exposure time and the number of operation increase. Stain-like impact traces might appear on the x-ray tube target surface by slight discharge in the course of the seasoning. These phenomena are one process to recover the withstanding voltage performance at that time. Therefore, if it is in stable operation at the maximum tube voltage of seasoning subsequent to them, the tube unit can be used without any interference to its electrical performance which in use.

Hot Products

Rotating Anode X-ray Tubes MWTX64-0.8_1.8-130

Rotating Anode X-ray Tubes MWTX64-0.8_1.8-130

Medical X-ray Tube XD3A

Medical X-ray Tube XD3A

Bone Desimeter X-ray Tube Brand Bx-1

Bone Desimeter X-ray Tube Brand Bx-1

 Rotating Anode X-ray Tubes 22 MWTX64-0.3_0.6-130

Rotating Anode X-ray Tubes 22 MWTX64-0.3_0.6-130

75KVDC High Voltage Cable WBX-Z75-T

75KVDC High Voltage Cable WBX-Z75-T

 Rotating Anode X-ray Tubes  MWTX73-0.6_1.2-150H

Rotating Anode X-ray Tubes MWTX73-0.6_1.2-150H

 Medical X-ray Collimator Automatic X-ray Collimator SR301

Medical X-ray Collimator Automatic X-ray Collimator SR301

Medical X-ray collimator Automatic x-ray collimator RF202

Medical X-ray collimator Automatic x-ray collimator RF202

Medical X-ray Tube CEI OX105-6

Medical X-ray Tube CEI OX105-6

HV Cable Receptacle 75KV HV Receptacle CA1

HV Cable Receptacle 75KV HV Receptacle CA1

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours